DKSH.com.au Suppliers Contact

Grabner Miniflash FP and FPH Vision

  • Description

Miniflash FP and FPH Vision

The flash point tester MINIFLASH FP Vision is uniquely designed to determine the flash points of liquids and solids. The analyzer uses Grabner flash point detection method, which is triggered by an energy-controlled electric arc and measures instantaneous pressure increase inside a closed chamber. By heating the test chamber from the top, the analyzer prevents condensation of high volatile compounds and guarantees improved test results.

MINIFLASH FP Vision continuously closed cup design and small sample volume of only 1-2 ml offer maximum safety. No offensive fumes are released in the testing area and little to no sample waste is registered when performing a flash point test. The fast thermoelectric cooling at the end of each flash point test plus the easy handling of the instrument also save expensive labor time.

MINIFLASH FP Vision is part of the Vision analyzer line. Vision analyzers support remote access to test results via the COCKPIT Software and are equipped with a full-color touchscreen. The touchscreen of the MINIFLASH Vision features an easy-to-use graphical interface and do away with the need for training. Any technician is capable of running a flash point test with MINIFLASH FP Vision! As other analyzers of the Vision product lineMINIFLASH FP Vision offers hassle-free communication with USB, Ethernet, LIMS and PCs and nearly unlimited storage capacity for test results.

Grabner Instruments offers two versions of MINIFLASH FP Vision: MINIFLASH FPH Vision, for high temperatures up to 400°C, and MINIFLASH FP Vision, for temperatures between -25°C and 120°C.

The flash point testers determine flash point according to ASTM D6450 and according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method. The official statement from the ASTM committee goes as follows: "there is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A”. Also, ASTM D7094 has been approved by the ASTM committee for the Diesel Fuel and Kerosene specifications ASTM D975, D396, D2880 and D3699.

 
Contact us
  • DKSH Australia Pty. Ltd.
  • 1 Beyer Road
  • Braeside VIC 3195
  • Australia

Shop online safely and securely

Visa and Mastercard accepted